Software parameters. ( xx is channel number )

Parameter 101.xx Receiver frequency..

Parameter 102.xx Transmitter frequency.

Parameter 103.xx Microcomputer clock offset - it should not be manually changed.

Parameter 104.xx Transmit Power :- NOTE 15 WATTS is maximum continuous power

0 = Transmit inhibited

1 = 1 watt

2 = 6 watts

3 = 10 watts

4 = 15 watts

5 = 25 watts

6 = 30 watts

 

Parameter 105.xx Squelch level:-

0 = open

1 = 9db sinad

2 = 12db sinad

3 = 15db sinad

4 = 18db sinad

5 = 21db sinad

6 = 24db sinad

Parameter 106.xx and 107.xx CTCSS Decode and Encode

  1. = 67
  2. = 71.9
  3. = 74.4
  4. = 77.0
  5. = 79.7
  6. = 82.5
  7. = 85.4
  8. = 88.5
  9. = 91.5
  10. = 94.8
  11. = 97.4
  12. = 100
  13. = 103.5
  14. = 107.2
  15. = 110.9
  16. = 114.8
  17. = 118.8
  18. = 123
  19. = 127.3
  20. = 131.8
  21. = 136.5
  22. = 141.3
  23. = 146.2
  24. = 151.4
  25. = 156.7
  26. = 162.2
  27. = 167.9
  28. = 173.8
  29. = 179.9
  30. = 166.2
  31. = 192.8
  32. = 203.5
  33. = 210.7
  34. = 218.1
  35. = 225.7
  36. = 233.6
  37. = 241.8
  38. = 250.3

0 = carrier squelch.

Parameter 108.xx ctcss controlled talkthrough 0 = disabled

Parameter 115.xx lockout channel 0 = channel not locked.

Parameter 140.xx switch on channel. 255 = last channel when base switched off

Parameter 324.xx Tx time limiter in seconds 0 = no limit

Parameter 333 low power ( if 340 is set to 1) tx power is set by this if the base is powered by dc

0 = Transmit inhibited

1 = 1 watt

2 = 6 watts

3 = 10 watts

4 = 15 watts

5 = 25 watts

Parameter 340 On mains power loss if 0 power is set by parameter 104, if 1 set by parameter 333

Parameter 353 talkthrough hang time 0 = 0, 1 = 2 seconds

ALL OTHER PARAMETERS ARE FACTORY SET AND MUST NOT BE ADJUSTED.

 

 